VX 29 H Local feed distribution amplifiers PG 11 glands
- Die cast housing
- Return amplifier and diplex filter on board
- Passive return path can be enabled by jumpers
- All adjustments by Rotary Switches or jumpers
Downstream >
Frequency range
85-1002 MHz
Gain single output
41 dB
Output level
CENELEC 42 ch
flat 6 dB slope
111 dBµV 114 dBµV
CSO, CTB
≥60 dB
Noise figure
up to 600 MHz
≤ 6 dB
up to 862 MHz
≤ 8 dB
Attenuator
Rotary switch 16 steps per 1 dB
0-15 dB
Equalizer
Rotary switch 16 steps per 1.5 dB
0-22.5 dB
Interstage equalizer
(Jumper)
0 / 6 / 12 dB
Interstage attenuator
0 / 5 dB
HF output test socket
directional coupler
-20 dB
Input test point
resistive test point
Upstream
5-65 MHz
Gain
active/ passive
24 dB ±0.5 dB / -4 dB
EN 50083-3 2nd, 3rd order
typ. 112 dBµV
Attenuator input/output
0/5 dB
0 / 3 / 6 / 9 dB
Operating voltage
27-65 VAC; 50/60 Hz
Power consumption
typ. 18 W
Power passing
per port
< 7 A
Connectors
PG11 glands
EMC
CE, Class A